PDU
-
12 Dekadood C19 Mining PDU
Tilmaamaha PDU:
1. Voltage Input: 3-wajiga 346-480 VAC
2. Input current: 3 x 80A
3. Voltage Output: hal-waji 200 ~ 277 VAC
4. Outlet: 12 dekedood ee C19 Sockets
5. Deked kastaa waxay leedahay 1P 20A Circuit Breaker
-
18 Dekadaha SA2-30 Mining PDU
Tilmaamaha PDU:
1. Voltage Input: 3-wajiga 346-480 VAC
2. Input current: 3 x 200A 3. Voltate Output: 3-phase 346-480 VAC
4. Outlet: 18 dekedood oo 3-waji ah SA2-30 Sockets, 2 C13 saldhigyada
5. Deked kastaa waxay leedahay 3P 20A Circuit Breaker
-
26 Dekadaha L16-30R Smart PDU
Tilmaamaha PDU:
1. Voltage Input: saddex-waji 346-415VAC
2. Gelitaanka hadda: 3 x 200A
3. Isku-dhafka 250A LS MCCB
4. Wax soo saarka hadda: saddex waji 346-415VAC
5. Weeladaha wax soo saarka: 26 dekedood L16-30R iyo 1 deked C13
6. Deked kasta oo L16-30R ah waxay leedahay UL489 3P 20A hydraulic magnetic circuit breaker, dekeda C13 waxay leedahay 1P 2A.
7. Wax soo saar kastaa wuxuu leeyahay interface shabakad u dhiganta
8. Kormeeraha fogaanta ee PDU iyo mid kasta oo deked ah hadda, danab, koronto, KWH
9. Kontoroolka fog ee deked kasta
-
24 Ports C19 PDU oo leh Network Switch
Tilmaamaha PDU:
1. Qalabka Shell: 1.2 SGCC Midabka: Budada madow
2. Voltage Input: 380-433Vac, WYE, 3N, 50/60 HZ
3. Korontada soo baxda: 220-250Vac
4. Max. Hadda: 160A
5. Socket soodhka: 24 dekedood C19 Lagu qiimeeyay 250V/20A
6. Habka xakamaynta iyo ilaalinta: Afar kasta oo 80A dareere magnetism Breaker
7. Silig gudaha ah: Siliga ugu weyn 2*5AWG, Laanta line 12AWG
-
18 Dekadood L7-30R Macdanta PDU
Tilmaamaha PDU:
1. Voltage Input: saddex-waji 346-480VAC
2. Gelitaanka hadda: 3 x 200A
3. Isku darka 200A Fuse ee saddexda weji
4. Wax soo saarka hadda: hal waji 200-277VAC
5. Weeladaha wax soo saarka: 18 deked L7-30R
6. Deked kastaa waxay leedahay UL489 1P 32A hydraulic magnetic circuit breaker
7. Deked kasta oo saddex-dekedood ah ayaa loo adeegi karaa iyada oo aan laga saarin daboolka PDU
8. marawaxada hawada gudaha ka soo bixisa oo leh 1P/2A
-
10 dekedood L16-30R macdanta PDU
Tilmaamaha PDU:
1. Input danab: 3-wajiga 346-480VAC
2. Gelitaanka hadda: 3 x 250A
3. Voltage Output: 3-wajiga 346-480 VAC
4. Outlet: 10 dekedood ee L16-30R Sockets
5. Deked kastaa waxay leedahay 3P 30A Circuit Breaker
-
HPC 24 Dekadaha C39 Smart PDU
Tilmaamaha PDU:
1. Voltage Input: 346-415V
2. Input current: 3*60A
3. Korontada soo baxda: 200-240V
4. Outlets: 24 dekedood ee saldhigyada C39 oo leh muuqaal is-quful ah
Socket ku habboon labada C13 iyo C19
5. Ilaalinta: 12pcs ee 1P20A UL489 wareegyada wareegga
Hal jabiye labadii gooboodba
7. Kormeeraha fogaanta ee PDU iyo mid kasta oo deked ah hadda, danab, koronto, KWH
8. Kontoroolka fog ee deked kasta
9. Smart Meter oo leh dekedaha Ethernet/RS485, taageera HTTP/SNMP/SSH2/MODBUS
-
36 dekedaha PA45 aasaasiga ah PDU
Tilmaamaha PDU
1. Voltage Input: 3-wajiga 346-480 VAC
2. Input current: 3*350A
3. Korontada wax soo saarka: 3-waji 346-480 VAC ama hal-waji 200-277 VAC
4. Outlet: 36 dekedood oo ah 6-pin PA45 Sockets oo loo habeeyey habka beddelka ah
5. PDU waxay ku habboon tahay 3-waji T21 iyo hal-waji S21
6. Xubin kasta oo 3P 30A ah ayaa koontaroolaysa 3 saldhig iyo hal 3P 30A jabiye ee Fanka
7. Isku-dhafka 350A ee wareegga ugu muhiimsan
-
24 dekedood P34 PDU aasaasiga ah ee cryptomining
Tilmaamaha PDU:
1. Voltage Input: 3-wajiga 346-480 VAC
2. Input current: 3x200A
3. Korontada wax soo saarka: 3-waji 346-480 VAC ama hal-waji 200-277 VAC
4. Outlet: 24 dekedood oo ah 6-pin PA45 Sockets oo loo habeeyey saddex qaybood
5. PDU waxay ku habboon tahay 3-waji T21 iyo hal-waji S21
6. Deked kastaa waxay leedahay 3p 25A Circuit Breaker
7. Tilmaamaha LED ee deked kasta
-
28 dekedood P34 PDU aasaasiga ah ee macdanta
Tilmaamaha PDU:
1. Input Voltage: saddex waji 346-480V
2. Gelitaanka Hadda: 3*400A
3. Korontada wax soo saarka: 3-waji 346-480V ama hal-waji 200-277V
4. Outlet: 28 dekedood oo ah 6-pin PA45 Sockets(P34) oo loo habeeyey saddex qaybood
5. PDU waxay ku habboon tahay 3-waji T21 iyo hal-waji S21
6. Deked kastaa waxay leedahay wareegtada Noork 3P 20A B1H3C20
-
12 dekedood P34 PDU aasaasiga ah
Tilmaamaha PDU:
1. Voltage Input: 3-wajiga 346-480 VAC
2. Input current: 3x125A
3. Korontada wax soo saarka: 3-waji 346-480 VAC ama hal-waji 200-277 VAC
4. Outlet: 24 dekedood oo ah 6-pin PA45 Sockets oo loo habeeyey saddex qaybood
5. PDU waxay ku habboon tahay 3-waji T21 iyo hal-waji S21
6. Deked kastaa waxay leedahay 3P 25A
7. Tilmaamaha LED ee deked kasta
-
12 dekedood P34 Smart PDU ee macdanta S21 T21
Tilmaamaha PDU:
1. Voltage Input: 3-wajiga 346-480 VAC
2. Input current: 3x125A
3. Korontada wax soo saarka: 3-waji 346-480 VAC ama hal-waji 200-277 VAC
4. Outlet: 12 deked 6-pin PA45 Sockets oo loo habeeyey saddex qaybood
5. Deked kastaa waxay leedahay 3p 25A
6. PDU waxay ku habboon tahay 3-waji T21 iyo hal-waji S21
7. Kormeeraha fog iyo xakamaynta ON/OFF ee deked kasta
8. Gelida kormeeraha fog-fog oo dhameeya deked kasta hadda, danabkeeda, korontadeeda, qodobka awoodda, KWH
9. Shaashadda LCD-ga korkeeda oo leh koontarool menu
10. Ethernet/RS485 interface, taageer HTTP/SNMP/SSH2/MODBUS/CA
11. Qaybta dhexe ee daboolka PDU waxaa laga saari karaa saldhigyada adeegga
12. PDU waxa lagu xidhi karaa in lagu xidho oo ay ciyaarto dareemayaasha heerkulka/huurka
13. Marawaxada hawo-mareenka gudaha oo leh tilmaame satus LED ah